Function ;
- Adopting two-wire system networking, integrated the power supply line, data signal line and acoustic signal wire into one wire with two cores. It makes the installation and maintenance simpler and assure system stable running.
- System data exchange controlling function to make the resource distribution of sub-station effectively.
- Offer sub stations power supplying and controlling,support real-time current/voltage monitoring function.
- Host call function is not based on the PC, so even PC has some faulty and can’t work, system still can realize the call, communication, system adjustment and alert function.
- High power amplifier function, so even in noise environment the voice number reporting and alert will be easy to hear.
- RJ45 networking port for call information transmission through TCP/IP.
- Max. Communication range 800m.
- Outline dimension [482*250*45mm]

Read More
Latest Products Image

PC SOFTWARE Yarward

PC SOFTWARE
Function ;
- PC software main interface displays the bed list. Adaptive resolution to display the whole wards and beds list.
- Support the patients information editing in the main display interface, supports hospital discharge operation.
- Support connecting with HIS and real-time patients information publishing, publishing content is customized.
- Support connecting with LCD TV, to realize the information display board function of beds list and nursing work list.
- Voice report function, support bed number, ward number and nursing class reporting. Support volume adjustment according different time period. Support voice reporting times adjustment.
- When calling, an eye-catching call form will pop up to make a call or call reply. Unprocessed calls can be automatically stored and reminded.
- Support higher nursing class call with priority, and can interrupt lower nursing classing call and talking.
- Support call recording checking and data output and analysis function.

Read More
Our Exceptional Solutions Image

YH-510WS YHE-916S

BEDSIDE STATION YH-510WS

Function ;
- Two wire networking, line size RVV2×0.5mm²,special suitable for old nurse ward upgrading.
- Alarm light supports nursing level indication function, supports max.25 colors, Optional light off time period to avoid effect patient rest.
- Device supports intercom and talkback function,. There’re obviously call buttons in both handset and bedside station main unit.Bedside station unit has Call Cancel button.
- There are one-key infusion drag replacement button in the handset. Press it to indicate the infusion drug replacement.
- Optional staff assist and code blue function
- Support call transfer function, support the communication with call from other wards.
- Support nurse present function. The nursing button in the corridor light(door light) and bedside station can indicate the nurse position.
- Online sub station number setting, for easy system adjustment and installation.
- Outlen Dimension (136mm*89mm*12mm).
- Instalation : Surface installation on wall or bed equipment zone.

Read More
Our Exceptional Solutions Image

YHE-6277 YHE-916S

YHE-6277 BATH STATION

Function ;
- For emergency call, with highest priority.
- Light and audio alarm when call, also broadcast in the ward zone.
- Cancel function for clear the error operation.
- IP68.
- Max consumption (0.5W)
- Outline Dimension ; 102mm*105mm**25mm, protrude thickness 12mm.
- Instalation : Installed in 86 mounting box, about 0.6-0.8m from the earth.

Read More
Our Exceptional Solutions Image

YHE-637S Yarward

YHE-637S CORRIDOR LIGHT

Function ;
- 25 color door corridor light, support different nursing levels indication.
- Installed near the door, related with the ward sub stations.
- Nursing button for nurse to process the call at the door.
- Outline Dimension ; 138*106*27mm

Read More
Our Exceptional Solutions Image

YHE-Z9S YARWARD

YHE-Z9S Cascade Connection Host

Function ;
- Two wire system power supply central controlling unit.
- Automatic recovery function of lightning protection,
- surge protection, short cicuit protection, grounding protection,
- overload protection and other multiple protection circuit system.
- Increase the load capacity of bus belt, so that the system can connection more extension hardware forwarding, without any delay.
- Outline Dimension : 428*250*45mm.

Read More
Our Exceptional Solutions Image

YHE-927 YARWARD

YHE-927 MEDICAL CARE HOST

Function ;
- A 25-color LED light is used to indicate the patient nursing class.Nursing level colors can be configured systematically.
- The handle adopts magnet adsorption design, which not only meets the reliability requirements, but also facilitates daily cleaning and wiping.
- The number of hospital ward and hospital bed can be displayed and broadcast by voice. The broadcasting times is adjusted. Support two broadcasting methods, circulation broadcasting and interval broadcasting.
- Medical care host can directly call to a patient terminal, realize two-way intercom operation.
- Support independent broadcast function, support to choose any bed through the screen for microphone broadcast function, convenient to do propaganda and education operations.
- The list of beds can be displayed in standard mode and simplified mode can show more beds at the same time, while standard mode can visually show more information content.
- Support call intercom, call display, call not processed reminder and one-key reset and other functions.
- System support max. 4 period call volume automatic adjustment function. Each period of time can be flexibly adjusted.
- It has functions of circuit detection, fault alarm, fault patrol and work log.
- The device supports the online upgrade function, and the program can be upgraded through the server.
- Installation : Handle on table or wall surface installation.
- Screen Size 10.1”
- Resolution 1024*600
- Outline Dimension ; 322*205*58mm.
- Operation ; Touch operation and button.

Read More
Our Exceptional Solutions Image

YHE-D208SC YARWARD

YHE-D208SC CORRIDOR DISPLAY

Function ;
- Double side Φ3.75 single red dot support 16x2 words/numbers,dot dia. 3.5mm.
- The call circularly displays the level of care, room number, and bed number
- Support display date, time, nurse location, warm tips and other content.
- Built-in speaker, support synchronous voice number
- Instalation ; Corridor ceiling installation or hanging installation.
- Outline Dimension : 826*190*53mm

Read More
Our Exceptional Solutions Image

YHE-X245K Yarward

YHE-X245K CORRIDOR DISPLAY

Function ;
- Corridor double sides display.
- Multi-function display, can display room number, bed number, call sequence number, time, etc
- PMMA acrylic panel engraving and processing into one body, with excellent transparent display effect.
- Maximum Consumption 5W.
- Work Voltage ; 20V.
- Outline Dimension ; 556mm*215mm**32mm.Br> - Instalation : Corridor ceiling installation.

. Read More
Our Exceptional Solutions Image

YHE-W82 WIRELESS YARWARD

YHE-W82 WIRELESS COMMUNICATION HOST

Function ;
- Automatic networking, can be used through the internal bus cascade, to achieve a large area of wireless coverage.
- Support to mount multiple mobile medical extension, wireless call button and other wireless terminals.
- Support two-way wireless data transmission.
- Support two-way wireless data transmission.Through communication with the calling system host, the function of intercom is realized.
- It has 40 independently set channels.
- Outline Dimension ; 218*143*38mm
- Instalation : It should be ceiling installed in the ward area. The effective signal coverage is 50 meters in diameter.

Read More
Our Exceptional Solutions Image

YHE-WR3 Yarward

YHE-WR3 MOBILE MECICAL STAFF UNIT

Function ;
- Wireless transmission of data and voice to meet the requirements of nurses to carry.
- Long standby time, meet more than one day of nursing use requirements.
- LCD display multiple call information, can directly answer intercom or clear processing.
- Call the nurse station and extension at any time to support reinforcement calls.
- The reminding mode can be set to ring, vibration and mute. The call volume can be adjusted at multiple levels.
- More than 40 communication channels are provided, each channel supports multiple wireless terminals.